CEMS - Hệ thống quan trắc khí thải tự động
Last update:
13/08/2021
SmartCem Datasheet 2 - CODEL - CEMS Document
4310 Views •ACX Gas Analyzer System-ABB CEMS Datashete
4305 Views •SmartCem Datasheet - CODEL - CEMS Document
4107 Views •EnergyTech 301 Datasheet Dust Monitor - CEMS CODEL
3948 Views •DCEM2000_2100 Datasheet Dust Monitoring - CODEL - CEMS Document
3846 Views •S700 Gas Analyzer-SICK catalogue-TAILOR-MADE-CEMS-Gas analysis
3710 Views •GCEM 40 Datasheet Gas Monitoring - CODEL - CEMS Document
3630 Views •ABB CEMS Datasheet-ABB CEMS solution and products information
3593 Views •GCEM 40E Datasheet Gas Monitoring - CODEL - CEMS Document
3566 Views •DCEM1000_1001 Dust Monitoring - CODEL - CEMS Document
3470 Views •PowerCEMS100-SICK catalogue-CEMS-EFFICIENT SYSTEM-Gas analysis for Power Plants
3447 Views •DustHunter T50-SICK catalogue-Transmittance dust measuring devices
3399 Views •FLOWSIC100-SICK catalogue-Volume Flow Measuring Device
3375 Views •VCEM5000_5100 Datasheet Flow Monitoring - CODEL - CEMS Document
3055 Views •EasyLine EL3000 Series-ABB CEMS Datasheet-Continuous Gas Analyzers
2800 Views •GCEM 4000 Datasheet Gas Monitoring - CODEL - CEMS Document
2796 Views •GCEM 4100 Datasheet Gas Monitoring - CODEL - CEMS Document
2723 Views •DCEM2000/2100 Opacity/Dust Monitor
In-situ, low maintenance devices for continuous monitoring of opacity/dust emissions
- % opacity or dust density in mg/Nm3
- Dual-pass, open-path transmissometer
- Integral auto zero and span check
- Dynamic misalignment check
- Full contamination check on all active optical surfaces
- Integral high efficiency air curtains for maximum uninterrupted service
The DCEM2000 and DCEM2100 provide a continuous measurement of opacity or dust concentration in flue gases by continuously measuring the transmissivity of visible light across a process duct or stack.
Its dual-pass optical arrangement is based on twin transmissometers measuring in opposing directions through the same section of the gas stream, providing not only an accurate average of the dust loading, but also providing a unique dynamic assessment of any misalignment errors due to stack movement.
The measurement of opacity or particulate (dust) emissions from a process stack by measuring changes in optical transmission is simple in concept, the monitor must be insensitive to any other factors that degrade the optical transmission such as contamination of optical surfaces or gross misalignment.
In-situ, low maintenance devices for continuous monitoring of opacity/dust emissions
- % opacity or dust density in mg/Nm3
- Dual-pass, open-path transmissometer
- Integral auto zero and span check
- Dynamic misalignment check
- Full contamination check on all active optical surfaces
- Integral high efficiency air curtains for maximum uninterrupted service
The DCEM2000 and DCEM2100 provide a continuous measurement of opacity or dust concentration in flue gases by continuously measuring the transmissivity of visible light across a process duct or stack.
Its dual-pass optical arrangement is based on twin transmissometers measuring in opposing directions through the same section of the gas stream, providing not only an accurate average of the dust loading, but also providing a unique dynamic assessment of any misalignment errors due to stack movement.
The measurement of opacity or particulate (dust) emissions from a process stack by measuring changes in optical transmission is simple in concept, the monitor must be insensitive to any other factors that degrade the optical transmission such as contamination of optical surfaces or gross misalignment.