CEMS - Hệ thống quan trắc khí thải tự động
Last update:
13/08/2021
SmartCem Datasheet 2 - CODEL - CEMS Document
4727 Views •ACX Gas Analyzer System-ABB CEMS Datashete
4652 Views •SmartCem Datasheet - CODEL - CEMS Document
4563 Views •EnergyTech 301 Datasheet Dust Monitor - CEMS CODEL
4411 Views •DCEM2000_2100 Datasheet Dust Monitoring - CODEL - CEMS Document
4239 Views •S700 Gas Analyzer-SICK catalogue-TAILOR-MADE-CEMS-Gas analysis
4050 Views •GCEM 40 Datasheet Gas Monitoring - CODEL - CEMS Document
3987 Views •GCEM 40E Datasheet Gas Monitoring - CODEL - CEMS Document
3945 Views •ABB CEMS Datasheet-ABB CEMS solution and products information
3913 Views •PowerCEMS100-SICK catalogue-CEMS-EFFICIENT SYSTEM-Gas analysis for Power Plants
3872 Views •DCEM1000_1001 Dust Monitoring - CODEL - CEMS Document
3838 Views •DustHunter T50-SICK catalogue-Transmittance dust measuring devices
3816 Views •FLOWSIC100-SICK catalogue-Volume Flow Measuring Device
3757 Views •VCEM5000_5100 Datasheet Flow Monitoring - CODEL - CEMS Document
3459 Views •GCEM 4000 Datasheet Gas Monitoring - CODEL - CEMS Document
3141 Views •EasyLine EL3000 Series-ABB CEMS Datasheet-Continuous Gas Analyzers
3109 Views •GCEM 4100 Datasheet Gas Monitoring - CODEL - CEMS Document
3062 Views •DCEM2000/2100 Opacity/Dust Monitor
In-situ, low maintenance devices for continuous monitoring of opacity/dust emissions
- % opacity or dust density in mg/Nm3
- Dual-pass, open-path transmissometer
- Integral auto zero and span check
- Dynamic misalignment check
- Full contamination check on all active optical surfaces
- Integral high efficiency air curtains for maximum uninterrupted service
The DCEM2000 and DCEM2100 provide a continuous measurement of opacity or dust concentration in flue gases by continuously measuring the transmissivity of visible light across a process duct or stack.
Its dual-pass optical arrangement is based on twin transmissometers measuring in opposing directions through the same section of the gas stream, providing not only an accurate average of the dust loading, but also providing a unique dynamic assessment of any misalignment errors due to stack movement.
The measurement of opacity or particulate (dust) emissions from a process stack by measuring changes in optical transmission is simple in concept, the monitor must be insensitive to any other factors that degrade the optical transmission such as contamination of optical surfaces or gross misalignment.
In-situ, low maintenance devices for continuous monitoring of opacity/dust emissions
- % opacity or dust density in mg/Nm3
- Dual-pass, open-path transmissometer
- Integral auto zero and span check
- Dynamic misalignment check
- Full contamination check on all active optical surfaces
- Integral high efficiency air curtains for maximum uninterrupted service
The DCEM2000 and DCEM2100 provide a continuous measurement of opacity or dust concentration in flue gases by continuously measuring the transmissivity of visible light across a process duct or stack.
Its dual-pass optical arrangement is based on twin transmissometers measuring in opposing directions through the same section of the gas stream, providing not only an accurate average of the dust loading, but also providing a unique dynamic assessment of any misalignment errors due to stack movement.
The measurement of opacity or particulate (dust) emissions from a process stack by measuring changes in optical transmission is simple in concept, the monitor must be insensitive to any other factors that degrade the optical transmission such as contamination of optical surfaces or gross misalignment.